<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>Facultad de Ingeniería Mecánica y Eléctrica</title>
<link href="https://hdl.handle.net/20.500.12893/5128" rel="alternate"/>
<subtitle/>
<id>https://hdl.handle.net/20.500.12893/5128</id>
<updated>2026-05-01T02:13:09Z</updated>
<dc:date>2026-05-01T02:13:09Z</dc:date>
<entry>
<title>Diseño de un puente grúa automatizado para incrementar la productividad en el transporte de equipos y material en COMECO SAC</title>
<link href="https://hdl.handle.net/20.500.12893/15161" rel="alternate"/>
<author>
<name>Romero Chinchay, Ronal David</name>
</author>
<id>https://hdl.handle.net/20.500.12893/15161</id>
<updated>2025-08-25T15:22:47Z</updated>
<published>2025-05-05T00:00:00Z</published>
<summary type="text">Diseño de un puente grúa automatizado para incrementar la productividad en el transporte de equipos y material en COMECO SAC
Romero Chinchay, Ronal David
El estudio planteó como objetivo diseñar un puente grúa automatizado para incrementar la productividad en el transporte de equipos y material en COMECO SAC. Se trato de un estudio aplicado, no experimental, cuantitativo y transversal. La muestra se conformó por una carga máxima de 10 toneladas (un elemento o mixta). La investigación aborda la situación actual de COMECO SAC en el proceso de transporte de equipos y materiales, caracterizado por tiempos prolongados de 45 minutos por movimiento para trasladar hasta 6.67 toneladas por hora y un costo diario de S/.1125.00. Se propone un diseño automatizado de puente grúa con capacidad de carga nominal de 10 toneladas, empleando acero ASTM A36 o A572, motores asíncronos de alta eficiencia, frenos electromagnéticos y un sistema de control avanzado con PLC, HMI y mando inalámbrico. El diseño incluye elementos como vigas de acero, motores WEG de 7.50 HP, engranajes de dientes rectos, rodamientos SKF y un modelado estructural validado en SolidWorks con un factor de seguridad mínimo de 3.096. El análisis de rentabilidad revela indicadores altamente favorables, como un VAN de S/.930524.94, TIR de 253.78% y recuperación de inversión en 5.12 meses, evidenciando su viabilidad técnica y económica para optimizar los procesos actuales. Finalmente, la productividad se incrementa en 500%, concluyendo que el diseño de la grúa puente automatizada es factible.; The objective of the study was to design an automated overhead crane to increase productivity in the transport of equipment and material at COMECO SAC. This was an applied, non-experimental, quantitative and cross-sectional study. The sample consisted of a maximum load of 10 tons (one element or mixed). The research addresses the current situation of COMECO SAC in the process of transporting equipment and materials, characterized by long times of 45 minutes per movement to move up to 6.67 tons per hour and a daily cost of S/.1125.00. An automated design of an overhead crane with a nominal load capacity of 10 tons is proposed, using ASTM A36 or A572 steel, high-efficiency asynchronous motors, electromagnetic brakes and an advanced control system with PLC, HMI and wireless remote control. The design includes elements such as steel beams, 7.50 HP WEG motors, spur gears, SKF bearings and a validated structural model in SolidWorks with a minimum safety factor of 3.096. The profitability analysis reveals highly favorable indicators, such as a NPV of S/.930524.94, IRR of 253.78% and investment recovery in 5.12 months, evidencing its technical and economic viability to optimize current processes. Finally, productivity is increased by 500%, concluding that the design of the automated bridge crane is feasible.
</summary>
<dc:date>2025-05-05T00:00:00Z</dc:date>
</entry>
<entry>
<title>Evaluación de la integridad mecánica de la tubería de Mill Sand mediante la técnica de ondas guiadas aplicada en la Mina Yanacocha -  Cajamarca</title>
<link href="https://hdl.handle.net/20.500.12893/14619" rel="alternate"/>
<author>
<name>Escajadillo Agapito, Jorge Luis</name>
</author>
<id>https://hdl.handle.net/20.500.12893/14619</id>
<updated>2025-08-07T02:33:30Z</updated>
<published>2018-04-04T00:00:00Z</published>
<summary type="text">Evaluación de la integridad mecánica de la tubería de Mill Sand mediante la técnica de ondas guiadas aplicada en la Mina Yanacocha -  Cajamarca
Escajadillo Agapito, Jorge Luis
Dado que las tuberías transportan materiales peligrosos y que una fuga podría&#13;
provocar importantes pérdidas y daños tanto a las personas como al medio ambiente,&#13;
deben inspeccionarse en los sectores minero y petrolero. Las discontinuidades en el&#13;
grosor de las tuberías no se identificaron con prontitud en varias empresas industriales&#13;
mineras y petroleras a lo largo de la historia, lo que provocó fallos por rotura con&#13;
efectos graves y permanentes, incluida la contaminación de la tierra, el agua, la flora&#13;
y la fauna. Por tanto, es preciso examinar la integridad mecánica de las tuberías&#13;
mientras transporten este tipo de material peligroso; sin embargo, los métodos de&#13;
inspección tradicionales, como la ultrasonografía, sólo examinan un número limitado&#13;
de regiones, ignorando la gran mayoría de ellas. Se propone la aplicación de una&#13;
técnica avanzada del estado de la técnica que localiza las ubicaciones precisas de los&#13;
mecanismos de daño para evaluar e identificar a tiempo posibles fallos con el fin de&#13;
evitar paradas imprevistas. Esta técnica evalúa cualitativamente la integridad&#13;
mecánica de las tuberías. Desde los procesos generales de inspección hasta su&#13;
aplicación en un ejemplo concreto, el objetivo de este proyecto de investigación es&#13;
ejecutar y describir la metodología de ondas guiadas. Los resultados recogidos&#13;
demostraron la enorme capacidad de la técnica de ondas instruidas para determinar&#13;
la integridad de las tuberías de proceso.&#13;
Este estudio demostró la eficacia de la técnica de ondas guiadas magnetostrictivas&#13;
para evaluar la integridad mecánica de las tuberías, localizando con precisión los&#13;
puntos de desgaste más críticos, estimando la vida útil restante de las tuberías y&#13;
evitando percances mortales.; Because pipelines in the mining and oil industries contain hazardous materials and&#13;
spills could result in significant losses and injury to both humans and the environment,&#13;
inspection is essential. There was never enough time in the past for various industrial&#13;
mining and oil firms to identify discontinuities that led to failures with major, irreversible&#13;
effects, such contaminating the land, water, flora, and fauna. The mechanical integrity&#13;
of pipelines carrying this kind of hazardous material must thus be assessed; however,&#13;
traditional inspection methods only cover a limited region, so excluding the evaluation&#13;
of the great majority of locations.&#13;
A sophisticated method from the previous generation is used to examine the&#13;
mechanical integrity of the lines qualitatively, pinpointing the precise locations of the&#13;
damage mechanisms to be evaluated and identifying any potential defects in order to&#13;
prevent unplanned stoppages. Beginning with the general inspection methods and&#13;
ending with the implementation in a particular case, this research project aims to apply&#13;
and describe the guided wave technique. The findings demonstrated the method's&#13;
considerable potential for assessing process pipe integration.&#13;
Since the location of the pipes' most critical wear was precisely identified, their&#13;
remaining life was calculated, and tragic incidents were avoided, this study&#13;
demonstrated the effectiveness of inspection utilizing the Magnestoestrivo-type guided&#13;
wave technology in assessing the mechanical integrity of piping.
</summary>
<dc:date>2018-04-04T00:00:00Z</dc:date>
</entry>
<entry>
<title>Estudio de viabilidad técnica y económica de un sistema de bombeo fotovoltaico para el predio Anaya en el caserío San Juan del distrito de Pítipo- Ferreñafe- Lambayeque</title>
<link href="https://hdl.handle.net/20.500.12893/13455" rel="alternate"/>
<author>
<name>Barboza Anaya, Alexander</name>
</author>
<id>https://hdl.handle.net/20.500.12893/13455</id>
<updated>2024-09-30T15:16:31Z</updated>
<published>2023-11-28T00:00:00Z</published>
<summary type="text">Estudio de viabilidad técnica y económica de un sistema de bombeo fotovoltaico para el predio Anaya en el caserío San Juan del distrito de Pítipo- Ferreñafe- Lambayeque
Barboza Anaya, Alexander
La presente tesis tubo por objetivo: Realizar el estudio de viabilidad técnica y económica de un sistema de bombeo fotovoltaico para el predio Anaya en el caserío san juan del distrito de Pítipo- Ferreñafe- Lambayeque. Debido la familia Anaya Bustamante utiliza una motobomba de 22 HP para el riego de 3 hectáreas de terreno de cultivo de maíz, pero las consecuencias de la utilización de este sistema de bombeo son el alto costo del combustible, así como el transporte (S/ 7 368 anual) y mantenimiento (S/ 2 760 anual) por lo cual la familia Anaya busca alternativas con la finalidad de reducir dichos gastos. De los resultados de la investigación se tiene: Se ha considerado 02 fuentes de irradiación solar, datos de la METEONORM y NASTEC de los cuales se ha obtenido un valor promedio anual de la irradiación solar promedio anual es de: 5,816 kW.h/m2&#13;
/día para METEONORM y de los datos de la NASTEC se ha obtenido la irradiación solar promedio anual es de: 5,47 kW.h/m2 /día. Para los cálculos se ha considerado los datos de NASTEC por ser más conservadores. Del cálculo de la cantidad de agua requerida&#13;
se ha obtenido que: la mayor demanda de agua promedio diaria se produce el mes de febrero con un valor de: 199,23 ( m3 dia ). La menor demanda de agua se produce el mes de junio con un valor de 113,62 ( m3 dia ). Con 9 m, de altura dinámica total y caudal de 40,17 m3/h se ha seleccionado la bomba sumergible PS2-4000 C-SJ42-2. Para el suministro de energía eléctrica se tiene un generador fotovoltaico conformado por 14 paneles fotovoltaicos de la marca JA SOLAR de 455 Wp. El tanque almacenamiento de agua será de 10x10x2 m. El presupuesto del sistema de bombeo fotovoltaico propuesto es de S/ 60 116,30; con una tasa de descuento del 12% y considerando un horizonte de 25 años se ha obtenido que el VAN= El VAN = S/.23 286,23 &gt; 0 y la TIR = 18 % por lo que la propuesta es viable. El periodo de recuperación del capital será en un tiempo de 5 años y 7 meses.
</summary>
<dc:date>2023-11-28T00:00:00Z</dc:date>
</entry>
<entry>
<title>Diseño de un sistema fotovoltaico conectado a red para autoconsumo domiciliario en la provincia de Chiclayo departamento de Lambayeque</title>
<link href="https://hdl.handle.net/20.500.12893/12885" rel="alternate"/>
<author>
<name>Sanchez Sanchez, Luis Alberto</name>
</author>
<id>https://hdl.handle.net/20.500.12893/12885</id>
<updated>2024-05-02T18:01:11Z</updated>
<published>2022-04-18T00:00:00Z</published>
<summary type="text">Diseño de un sistema fotovoltaico conectado a red para autoconsumo domiciliario en la provincia de Chiclayo departamento de Lambayeque
Sanchez Sanchez, Luis Alberto
El objeto de la presente investigación fue: Diseñar un sistema fotovoltaico conectado a red para autoconsumo domiciliario en la provincia de Chiclayo departamento de Lambayeque. Luego de procesar la información se obtuvo que: De los recibos por consumo de energía eléctrica facilitados por el usuario se ha obtenido que el consumo promedio diario para el año 2019 según los datos obtenidos fue de 16,11 kW.h, además se observó que el mayor consumo de energía eléctrica se produjo en el mes de enero. De los datos de ambas fuentes para el caso de la NASA se obtiene que la irradiación solar promedio es de 5,83 kW.h/m2/día y en el caso de los datos de NASTEC irradiación solar promedio es de 5,42 kW.h/m2/día. Para los cálculos se utilizó el valor de: 5,42 kW.h/m2/día. El generador fotovoltaico estará conformado por 10 paneles fotovoltaicos de la marca JA SOLAR con una potencia 455 Wp c/u, y la potencia del generador fotovoltaico es de 4,55 kWp. El inversor es de la marca HUAWEI, modelo SUN2000L-3,68KTL, además de conductores eléctricos y equipos de protección. Se realizó el cálculo del sistema conectado a red el cual asciende a un valor de: S/ 20 528,68. Con una tasa de descuento del 15 % se realizó la evaluación económica para un horizonte de 25 años, de donde se obtuvo que el VAN= S/ 27 738,09 y la TIR= 28 %; el periodo de recuperación del capital es de:4 años y 5 meses. Por lo que la propuesta es viable técnica y económicamente.
</summary>
<dc:date>2022-04-18T00:00:00Z</dc:date>
</entry>
</feed>
