dc.description.abstract | La presente investigación se orientó a realizar el análisis sismorresistente del local institucional N°11015 Comandante Elías Aguirre, distrito de Chiclayo, provincia de Chiclayo, región Lambayeque, haciendo una comparativa entre las normativas peruana E.030 (2019), chilena Nch433 (2012), ecuatoriana NEC-SE-DS (2015) y mexicana NTC (2020); para luego determinar con cuál de las normas en estudio se comportaba la edificación más rígida, mediante la realización un contraste de resultados. Primero se realizó un análisis documental que, nos permitió la recopilación y selección de datos respecto de las normas previamente señaladas, para seleccionar los parámetros sismorresistentes a emplear; posterior a ello, se realizó el modelado de los cinco módulos del local institucional en el programa ETABS, en donde se analizó cada módulo bajo los parámetros establecido con cada normativa evaluada, obteniendo los resultados del análisis sismorresistente. Así también, luego del análisis, se verifico que con la norma E.030 cumplió las derivas mediante el análisis estático en 90% y análisis dinámico 100%; con la norma Nch433 cumplió los desplazamiento relativos al centro de masa y cualquier punto de la planta mediante el análisis estático y dinámico en un 100%; con la NEC-SE-DS mediante análisis estático y dinámico cumplió en un 100% las derivas; y con la NTC solo se analizó con el análisis dinámico cumpliendo en un 100% las derivas tanto para el estado límite de prevención de colapso como el estado límite de limitación de daños. Concluyendo luego del análisis de los resultados que, el local institucional N°11015 Comandante Elías Aguirre se comporta más rígido con la normativa ecuatoriana NEC-SE-DS (2015) seguido de las normas NTC (2020), Nch433 (2012) y E.030 (2019). | es_PE |
dc.description.abstract | The present investigation was aimed at carrying out the earthquake-resistant analysis of the institutional premises N°11015 Comandante Elías Aguirre, district of Chiclayo, province of Chiclayo, Lambayeque region, making a comparison between the Peruvian regulations E.030 (2019), Chilean Nch433 (2012), Ecuadorian NEC-SE-DS (2015) and Mexican NTC (2020); to then determine with which of the standards under study the building behaved the most rigid, by carrying out a contrast of results. First, a documentary analysis was carried out that allowed us to collect and select data regarding the previously indicated standards, to select the earthquake- resistant parameters to be used; After that, the modeling of the five modules of the institutional premises was carried out in the ETABS program, where each module was analyzed under the parameters established with each evaluated regulation, obtaining the results of the earthquake- resistant analysis. Likewise, after the analysis, it was verified that with the E.030 standard it complied with the drifts through static analysis in 90% and dynamic analysis 100%; with the Nch433 standard it complied with the displacement relative to the center of mass and any point of the plant through static and dynamic analysis in 100%; with the NEC-SE-DS through static and dynamic analysis it complied 100% with the drifts; and with the NTC it was only analyzed with the dynamic analysis, complying 100% with the drifts for both the limit state of prevention of collapse and the limit state of limitation of damages. Concluding after the analysis of the results that, the institutional premises N°11015 Comandante Elías Aguirre behaves more rigidly with the Ecuadorian regulations NEC-SE-DS (2015) followed by the NTC standards (2020), Nch433 (2012) and E.030 (2019). | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
dc.source | Universidad Nacional Pedro Ruiz Gallo | es_PE |
dc.source | Repositorio Institucional - UNPRG | es_PE |
dc.subject | Normas de construcción | es_PE |
dc.subject | Ingeniería antisísmica | es_PE |
dc.subject | Edificios escolares | es_PE |
dc.subject | School buildings | es_PE |
dc.subject | Earthquake engineering | es_PE |
dc.subject | Construction standards | es_PE |
dc.title | Análisis sismorresistente del local institucional N°11015 Comandante Elías Aguirre, distrito de Chiclayo, provincia de Chiclayo, región Lambayeque | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Ingeniero Civil | es_PE |
thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitectura | es_PE |
thesis.degree.discipline | Ingeniería Civil | es_PE |
dc.type.version | info:eu-repo/semantics/draft | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
renati.author.dni | 75133383 | |
renati.author.dni | 70454951 | |
renati.advisor.dni | 16716243 | |
renati.advisor.orcid | https://orcid.org/0000-0002-9558-2853 | es_PE |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
renati.discipline | 732016 | es_PE |
renati.juror | Rodríguez Serquén, Segundo Arturo | es_PE |
renati.juror | Ramos Chimpen, Carlos Jorge | es_PE |
renati.juror | Cachay Silva, Roberto Carlos | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Ingeniería Civil [296]