Mostrar el registro sencillo del ítem

dc.contributor.advisorRivera Vásquez, Juan Pedroes_PE
dc.contributor.authorCueva Pérez, Jonatan Giezees_PE
dc.date.accessioned2025-04-01T17:44:51Z
dc.date.available2025-04-01T17:44:51Z
dc.date.issued2025-02-10
dc.identifier.urihttps://hdl.handle.net/20.500.12893/14366
dc.description.abstractEn teleterapia en nuestra actualidad se ha visto necesario ver el modo posible para minimizar la afección a órganos circundantes durante el tratamiento a un paciente, es decir los especialistas necesariamente su objetivo es minimizar el tumor hasta erradicarlo. En base a esto este trabajo se ha visto necesario realizar la caracterización de los dosímetros MOSFET y que parámetros tomar en cuenta para su buen uso durante el tratamiento in vivo. Al realizar un estudio exhaustivo de los parámetros de los MOSFET se debe obtener una respuesta similar comparada a otros trabajos de investigación, de esta manera al medir la dependencia angular a la que puede ser sometido el MOSFET se encontró que la respuesta de cada MOSFET no sufría variación mínima de 0.6%, en el caso de la dependencia con la tasa de dosis se muestra la respuesta del dosímetro MOSFET expuesto a energías de Co-60 fue estadísticamente insignificante con una desviación standard de R2=0.0794, también se tomaron lecturas de linealidad con la dosis el cual obtuvimos respuestas satisfactorias a comparación de otros estudios ya realizados con un 1% para una respuesta promedio de los MOSFET de 203.38mV, con R^2=0.9993 por último la reproducibilidad con la dosis se tomaron medidas con cada uno de los dosímetros manteniendo la dosis asignada de 630 MU/min de este modo se obtuvo una excelente respuesta por parte de los MOSFET. Cada uno de los resultados que se obtuvieron fueron satisfactorios ya que por recomendación se tiene que los MOSFET tienen una gran capacidad de sensibilidad para dar respuestas in vivo lo que ayudaría a los especialistas en hacer de su uso infaltable, para proporcionarles el excedente de tasa de dosis especifica o una dosis acumulada durante el tratamiento.es_PE
dc.description.abstractIn today's teletherapy, it has been necessary to see the possible way to minimize the impact on surrounding organs during the treatment of a patient, that is, specialists necessarily aim to minimize the tumor until it is eradicated. Based on this, this work has seen it necessary to characterize the MOSFET dosimeters and what parameters to take into account for their proper use during in vivo treatment. When carrying out an exhaustive study of the MOSFET parameters, a similar response should be obtained compared to other research works. In this way, when measuring the angular dependence to which the MOSFET can be subjected, it was found that the response of each MOSFET did not suffer. minimum variation of 0.6%, in the case of dependence on the dose rate, the response of the MOSFET dosimeter exposed to Co-60 energies was shown to be statistically insignificant with a standard deviation of R2=0.0794, linearity readings were also taken with the dose which we obtained satisfactory responses compared to other studies already carried out with 1% for an average response of the MOSFETs of 203.38mV, with R^2=0.9993. Finally, the reproducibility with the dose, measurements were taken with each one of the dosimeters maintaining the assigned dose of 630 MU/min, in this way an excellent response was obtained from the MOSFETs. Each of the results obtained were satisfactory since it is recommended that MOSFETs have a great sensitivity capacity to provide responses in vivo, which would help specialists in making their use inevitable, to provide them with the excess rate of response. specific dose or a cumulative dose during treatment.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Pedro Ruiz Galloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectTeleterapiaes_PE
dc.subjectDosímetroses_PE
dc.subjectRadiación ionizantees_PE
dc.titleCaracterización de Dosímetros MOSFET para ser usados en Teleterápiaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameLicenciado en Físicaes_PE
thesis.degree.grantorUniversidad Nacional Pedro Ruiz Gallo. Facultad de Ciencias Físicas y Matemáticases_PE
thesis.degree.disciplineFísicaes_PE
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.03.01es_PE
renati.author.dni71561880
renati.advisor.dni16778525
renati.advisor.orcidhttps://orcid.org/0000-0003-3428-7639es_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline533056es_PE
renati.jurorCieza Ramos, Arnulfoes_PE
renati.jurorPrada Marchena, Jara Hernanes_PE
renati.jurorSolano Salazar, Franciscoes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess
Universidad Nacional Pedro Ruiz Gallo

Calle Juan XXIII 391 Lambayeque - Perú | Telf. 283146 - 283115 - 282120 - 282356

Todos los contenidos de repositorio.unprg.edu.pe están bajo la Licencia Creative Commons v.4.0

repositorio@unprg.edu.pe