Mostrar el registro sencillo del ítem
Comparación de los niveles de referencia para los procedimientos de rayos X (Rx) de Tórax en pacientes COVID POST COVID
dc.contributor.advisor | Curo Maquén, Luis Alberto | es_PE |
dc.contributor.author | Inoñan Fernandez, Jose Eulogio | es_PE |
dc.contributor.author | Fonseca Valle, Jayleny Esmit | es_PE |
dc.date.accessioned | 2025-04-02T16:11:07Z | |
dc.date.available | 2025-04-02T16:11:07Z | |
dc.date.issued | 2025-01-31 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12893/14374 | |
dc.description.abstract | El principal objetivo del presente trabajo de investigación fue comparar los niveles de referencia para los procedimientos de rayos X (Rx) de tórax en pacientes Covid y Post Covid propuesto por la Comisión Internacional Protección Radiológica con los valores obtenidos en el Centro Médico Medisag Chiclayo – 2023. Desde una perspectiva metodológica, se utilizó la consola de rayos X, mientras que, en términos de materiales, empleamos placas radiográficas. Como herramienta clave, contamos con el informe técnico de control de calidad del equipo de rayos X. La población y muestra estuvo conformada por pacientes que han sido sometidos a rayos (Rx) torácica para diagnóstico de Covid en el Centro de Salud MEDISAG. Como principales resultados se observó que la densidad de los niveles de referencia en pacientes Covid y Post-Covid es distinta, a un nivel de significancia del 5% y un valor t de 9.707. La latitud radiográfica y el contraste radiográfico de los niveles de referencia en pacientes Covid y Post-Covid es distinta, a un nivel de significancia de 5% y un valor t de -15.7. Asimismo, la sensibilidad de los niveles de referencia en pacientes Covid y Post Covid es distinta, a un nivel de significancia de 5% y un valor t de 34.9. Como conclusión principal, los hallazgos de los resultados resaltaron la importancia de una cuidadosa monitorización y seguimiento de los pacientes post-COVID. Los niveles de referencia podrían indicar la necesidad de un manejo continuo y específico para garantizar una recuperación óptima y prevenir posibles complicaciones a largo plazo. | es_PE |
dc.description.abstract | The main objective of this research work was to compare the reference levels for chest X- ray (Rx) procedures in Covid and Post Covid patients proposed by the International Radiological Protection Commission with the values obtained at the Medisag Chiclayo Medical Center – 2023 From a methodological perspective, the X-ray console was used, while, in terms of materials, we used radiographic plates. As a key tool, we have the technical quality control report of the The main results were that the density of the reference levels in Covid and Post-Covid patients is different, at a significance level of 5% and a t value of 9.707. The radiographic latitude and radiographic contrast of the reference levels in Covid and Post-Covid patients is different, at a significance level of 5% and a t value of -15.7. Likewise, the sensitivity of the reference levels in Covid and Post Covid patients is different, at a significance level of 5% and a t value of 34.9. As a main conclusion, the findings of the results highlighted the importance of careful monitoring and follow-up of post-COVID patients. Baseline levels may indicate the need for ongoing, targeted management to ensure optimal recovery and prevent potential long-term complications. | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
dc.subject | Rayos X | es_PE |
dc.subject | Latitud radiográfica | es_PE |
dc.subject | Radiología del tórax | es_PE |
dc.title | Comparación de los niveles de referencia para los procedimientos de rayos X (Rx) de Tórax en pacientes COVID POST COVID | es_PE |
dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
thesis.degree.name | Licenciado en Física | es_PE |
thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo. Facultad de Ciencias Físicas y Matemáticas | es_PE |
thesis.degree.discipline | Física | es_PE |
dc.type.version | info:eu-repo/semantics/acceptedVersion | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#1.03.03 | es_PE |
renati.author.dni | 73088212 | |
renati.author.dni | 73031780 | |
renati.advisor.dni | 17594217 | |
renati.advisor.orcid | https://orcid.org/0000-0001-5646-3264 | es_PE |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
renati.discipline | 533056 | es_PE |
renati.juror | Mendoza Gamarra, Alfonso Ausberto | es_PE |
renati.juror | Prada Marchena, Jara Hernán | es_PE |
renati.juror | Salazar Ordinola, Francisco Solano | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Física [52]