Mostrar el registro sencillo del ítem

dc.contributor.advisorCuro Maquen, Luis Albertoes_PE
dc.contributor.authorAgapito Nuntòn, Segundo Gaspares_PE
dc.date.accessioned2025-07-24T14:30:11Z
dc.date.available2025-07-24T14:30:11Z
dc.date.issued2025-04-02
dc.identifier.urihttps://hdl.handle.net/20.500.12893/14980
dc.description.abstractLos niveles de referencia de dosis de para Chiclayo, el de -clínica de diagnóstico por imágenes RESUMEN estudios pediátricos se establecen radiación utilizando informes de estudios anteriores y protocolos específicos para diferentes tipos de diagnósticos, Estos niveles de referencia brindan directrices para asegurarse de que la exposición del paciente esté dentro de un rango seguro. hasta el momento es muy invaluable establecer niveles de referencia en pacientes pediátricos ya que son los pacientes más vulnerables por efectos de la radiación, en la en objetivo principal este presente tema de investigación se basó en la Evaluación de los niveles de referencia y Dosis Efectiva en radiografía general torácica en pacientes pediátricos en la clínica de diagnóstico por imágenes de Chiclayo-2023. Se utilizó una metodología Se recolectaron 80 exámenes de radiografía de tórax de pacientes pediátricos entre edades comprendidos (1-5 años), este tipo de investigación está fundamentada en cl análisis de parámetros técnicos, físicos y dosimétricos asociados a las pruebas radiológicas de tórax en pacientes infantiles, donde se obtuvieron como resultados acerca dosimétrica la eficaz para radiografía pediátrica de tórax en la Clínica Radiológica de Chiclayo evidencian prácticas seguras, con un promedio de 2,93 años y un peso de 14.6 kg. Se ajustaron correctamente los parámetros técnicos (64,21 kV, 2,35 mAs y 8,75 ms), lo que condujo a una dosis superficial media de 4,27 mGy y una dosis efectiva de 0,01 mSv. Concluyendo que los las efectivas proyectadas la clínica Chiclayo para el 2023 se encuentran en concordancia con normas internacionales como la ICRP y las pautas europeas. La dosis media efectiva de 0,010 mSv muestra una adecuada protección contra radiación, equiparable a centros como CERIN.es_PE
dc.description.abstractadiation dose reference levels for pediatric studies are established using previous study reports and specific protocols for different types of diagnoses, these reference levels provide guidelincs to make sure that paticnt cxposurc is within a safe rangc. So far it is very invaluable vulnerable natients Chiclayo, effects radiation, present research topic since they are most diagnostic imaging clinic in based on Evaluation of reference levels and Effective Dose in general thoracic radiography in pediatric patients in the diagnostic imaging elinic of Chiclayo-2023. A methodology was used. 80 chest x-ray examinations were collected from pediatric patients between the ages of (1-5 years). This type of research is based on the analyxis of technical, physical and dosimetric parameters associated with chest radiological tests in pediatric patients, where the results about the dosimetric reference levels (NRD) pediatric chest at Radiological Clinie of Chiclayo were obtained, showing safe practices, with an average of 2.93 years and a weight of 14.6 kg. The technical parameters were correctly adjusted (64.21 kV, 2.35 mAs and 8.75 ms), which led to a mean surface dose of 4.27 mGy and an effective dose of 0.01 mSv. It was concluded that the reference dose levels (RDL) and the effective doses projected at the Chiclayo clinic for 2023 are in accordance with international standards such as the ICRP and European guidelines. The average effective dose of 0.010 mSv shows adequate radiation protection, comparable to centres such as CERIN.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Pedro Ruiz Galloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectReferencia para Diagnosticoes_PE
dc.subjectProtección radiologicaes_PE
dc.subjectDosis de radiaciónes_PE
dc.titleEvaluación en niveles de referencia dosimétrica y dosis efectiva para radiografía pediátrica de tórax en la clínica radiológica de chiclayo-2023es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameLicenciado en Físicaes_PE
thesis.degree.grantorUniversidad Nacional Pedro Ruiz Gallo - Facultad de Ciencias Físicas y Matemáticases_PE
thesis.degree.disciplineFísicaes_PE
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.03.04es_PE
renati.author.dni48278758
renati.advisor.dni17594217
renati.advisor.orcidhttps://orcid.org/0000-0001-5646-3264es_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline533056es_PE
renati.jurorMendoza Gamarra, Alfonso Ausbertoes_PE
renati.jurorPrada Marchena, Jara Hernánes_PE
renati.jurorSalazar Ordinola, Francisco Solanoes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess
Universidad Nacional Pedro Ruiz Gallo

Calle Juan XXIII 391 Lambayeque - Perú | Telf. 283146 - 283115 - 282120 - 282356

Todos los contenidos de repositorio.unprg.edu.pe están bajo la Licencia Creative Commons v.4.0

repositorio@unprg.edu.pe