Mostrar el registro sencillo del ítem
Evaluación del desempeño sísmico del edificio de la Facultad de Enfermería de la Universidad Nacional Pedro Ruiz Gallo, mediante un Análisis No Lineal de Historia de Respuesta empleando el Apéndice A del ACI.318.19
| dc.contributor.advisor | Serrano Zelada, Ovidio | es_PE |
| dc.contributor.author | Santos Correa, Jonnatan Manuel | es_PE |
| dc.contributor.author | Torres Zavaleta, André Martín | es_PE |
| dc.date.accessioned | 2025-10-27T14:46:25Z | |
| dc.date.available | 2025-10-27T14:46:25Z | |
| dc.date.issued | 2025-10-03 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12893/15527 | |
| dc.description.abstract | Este trabajo de investigación tiene como objetivo realizar la verificación no lineal del edificio de la facultad de Enfermería de la Universidad Nacional Pedro Ruiz Gallo, empleando el Apéndice A del ACI 318-19. La edificación presenta por característica un sistema conformado por muros estructurales y consta de 5 pisos más azotea, la misma que fue diseñada bajo normativa técnica peruana. La evaluación del desempeño comprendió, en primera instancia, la verificación lineal según la norma E.030-2018 con la finalidad de evaluar irregularidades, derivas y relación de demanda capacidad en elementos estructurales, y en segunda instancia, la realización del Análisis No Lineal Tiempo Historia (ANLTH) según el Apéndice A con la finalidad de evaluar el desempeño global de la estructura y el desempeño local en los elementos. Determinando así la necesidad de incorporar un sistema de protección sísmica con disipadores de energía Shear Link Bozzo (SLB). Finalmente, se determina que la edificación no cumple el objetivo de desempeño de seguridad de vida (LS) ante la acción del sismo máximo considerado (MCE) requerido para edificaciones esenciales. Destacando que la incorporación de los SLB contribuye a un mejor comportamiento sísmico. | es_PE |
| dc.description.abstract | This research study aims to perform a Nonlinear verification of the Nursing Faculty building at the Pedro Ruiz Gallo National University, using Appendix A of ACI 318-19. The building features a system composed of structural walls and consists of five floors plus a roof terrace, which was designed under Peruvian technical regulations. The performance evaluation included, first, a linear verification according to Standard E.030-2018 to assess irregularities, drifts, and demand-capacity relationships in structural elements. Second, a Nonlinear Time History Analysis (NLTHA) was performed according to Appendix A to assess the overall performance of the structure and the local performance of the elements. This determined the need to incorporate a seismic protection system with Shear Link Bozzo (SLB) energy dissipators. Finally, it was determined that the building does not meet the life safety (LS) performance objective for the maximum considered earthquake (MCE) required for essential buildings. It is emphasized that the incorporation of SLBs contributes to improved seismic performance. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Desempeño sísmico | es_PE |
| dc.subject | Sismoresistente | es_PE |
| dc.subject | Disipadores SLB | es_PE |
| dc.subject | Seismic performance | es_PE |
| dc.title | Evaluación del desempeño sísmico del edificio de la Facultad de Enfermería de la Universidad Nacional Pedro Ruiz Gallo, mediante un Análisis No Lineal de Historia de Respuesta empleando el Apéndice A del ACI.318.19 | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Civil | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitectura | es_PE |
| thesis.degree.discipline | Ingeniería Civil | es_PE |
| dc.type.version | info:eu-repo/semantics/acceptedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.00 | es_PE |
| renati.author.dni | 73018843 | |
| renati.author.dni | 71071034 | |
| renati.advisor.dni | 16716243 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-9558-2853 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 73201 | es_PE |
| renati.juror | Farías Feijoo, Juan Herman | es_PE |
| renati.juror | Huangal Castañeda, Nelson Enrique | es_PE |
| renati.juror | Cachay Silva, Roberto Carlos | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Ingeniería Civil [325]