Diseño de sistema inmótico para reducir el consumo de energía eléctrica en el Área de Hospitalización del Hospital Regional de Lambayeque
| dc.contributor.advisor | Villalobos Cabrera, Jony | es_PE |
| dc.contributor.author | Sánchez Bernal, Luis Felipe | es_PE |
| dc.date.accessioned | 2025-11-25T17:23:23Z | |
| dc.date.available | 2025-11-25T17:23:23Z | |
| dc.date.issued | 2025-09-24 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12893/15711 | |
| dc.description.abstract | El Hospital Regional de Lambayeque se beneficia de un suministro eléctrico de Media Tensión que es proporcionado por la empresa concesionaria conocida como Electronorte S.A. Este servicio se rige bajo un tarifario específico, identificado como MT-3. Además, el hospital ha contratado una potencia total que asciende a 982,0000 kilovatios. En cuanto a su consumo, el promedio mensual de energía eléctrica utilizada por la institución se sitúa alrededor de 292,390.8427 kilovatios hora por mes. De la totalidad de este consumo, un 25% se asigna específicamente al Área de Hospitalización que forma parte del Hospital. Por esta razón, el objetivo primordial consiste en la creación y desarrollo de un sistema inmótico que tenga como finalidad disminuir de manera significativa el consumo de energía eléctrica en el área de hospitalización del Hospital Regional de Lambayeque. La investigación que se está llevando a cabo se clasifica como un tipo de investigación Aplicada, que tiene como objetivo resolver problemas prácticos y contribuir a la mejora de situaciones específicas. Por otro lado, el diseño utilizado en este estudio es de carácter No Experimental, lo que significa que no se manipulan las variables en un entorno controlado, sino que se observa y se analizan los fenómenos tal como ocurren en su contexto natural. Las conclusiones a que se arribaron son: El Área de Hospitalización del Hospital Regional de Lambayeque, tiene un consumo mensual es de 59576.71 kW-h y una facturación mensual promedio es S/.23 830,684. El sistema inmótico que permita gestionar en forma remota, eficaz y automatizada el consumo energético del Área de Hospitalización del Hospital Regional de Lambayeque constará: Sistema EIB-KNX, que emplea las normas EN50090, EN13321-1:2006 e ISO/IEC 14543, el mismo estará constituido por 59 fuentes de alimentación, D-Link fieles outdoor bridge 802.11b, un Ethernet UDP/IP, 59 detectores de humo, 59 sensores de luminosidad, 59 sensores de humedad, 59 reguladores de temperatura, 59 acopladores de Área/ Línea, 59 receptores IR, 02 cerraduras Tubular. El Sistema Inmótico permitirá un ahorro de energía al mes de 33000 kW-h y un ahorro mensual de S/. 26 400,00. La inversión a realizar para instalar el Sistema Inmótico es de S/.161 845,00, y los gastos de mantenimiento anual ascienden a S/.2 000,00, y como resultado de la evaluación económica en un periodo de 20 años y una tasa de interés de 12% se obtiene un VAN de S/. 20 409,42 una TIR de 14%. | es_PE |
| dc.description.abstract | The Lambayeque Regional Hospital benefits from a medium-voltage electricity supply provided by the concessionaire company Electronorte S.A. This service is governed by a specific tariff, identified as MT-3. In addition, the hospital has contracted a total power of 982,000 kilowatts. Regarding consumption, the institution's average monthly electricity use is approximately 292,390.8427 kilowatt hours. Of this total consumption, 25% is specifically allocated to the Inpatient Area, which is part of the hospital. For this reason, the primary objective is the creation and development of a building automation system that aims to significantly reduce electricity consumption in the inpatient area of the Lambayeque Regional Hospital. The research being conducted is classified as applied research, which aims to solve practical problems and contribute to the improvement of specific situations. Furthermore, the design used in this study is non-experimental, meaning that variables are not manipulated in a controlled environment. Instead, phenomena are observed and analyzed as they occur in their natural context. The conclusions reached are: The Inpatient Area of the Lambayeque Regional Hospital has a monthly consumption of 59,576.71 kWh and an average monthly bill of S/. 23,830,684. The building automation system that allows remote, efficient and automated management of energy consumption in the Hospitalization Area of the Lambayeque Regional Hospital will consist of: EIB-KNX System, which uses the EN50090, EN13321-1:2006 and ISO/IEC 14543 standards, it will consist of 59 power supplies, D-Link fieles outdoor bridge 802.11b, an Ethernet UDP/IP, 59 smoke detectors, 59 brightness sensors, 59 humidity sensors, 59 temperature regulators, 59 Area/Line couplers, 59 IR receivers, 02 Tubular locks. The Building Automation System will allow a monthly energy saving of 33,000 kW-h and a monthly saving of S/. 26,400.00. The investment to be made to install the Inmotic System is S/. 161,845.00, and the annual maintenance costs amount to S/. 2,000.00, and as a result of the economic evaluation over a period of 20 years and an interest rate of 12%, an NPV of S/. 20,409.42 and an IRR of 14% is obtained. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Sistema Inmótico | es_PE |
| dc.subject | Consumo de Energía Eléctrica | es_PE |
| dc.subject | Iluminación | es_PE |
| dc.subject | Building Automation System | es_PE |
| dc.subject | Electricity Consumption | es_PE |
| dc.subject | Lighting | es_PE |
| dc.title | Diseño de sistema inmótico para reducir el consumo de energía eléctrica en el Área de Hospitalización del Hospital Regional de Lambayeque | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Mecánico Electricista | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Mecánica y Eléctrica | es_PE |
| thesis.degree.discipline | Ingeniería Mecánica y Eléctrica | es_PE |
| dc.type.version | info:eu-repo/semantics/submittedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.02.01 | es_PE |
| renati.author.dni | 73335478 | |
| renati.advisor.dni | 16699530 | |
| renati.advisor.orcid | https://orcid.org/0000-0003-3643-5498 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 713076 | es_PE |
| renati.juror | Tumialan Hinostroza, Juan Antonio | es_PE |
| renati.juror | Carranza Montenegro, Daniel | es_PE |
| renati.juror | Niño Vásquez, Percy | es_PE |