| dc.description.abstract | La presente tesis se centra principalmente en analizar cómo se desempeña sísmicamente los bloques III, IV y tanque elevado pertenecientes a la I.E Santa Magdalena Sofía ubicada en la ciudad de Chiclayo, provincia de Chiclayo, departamento de Lambayeque. Se utilizará el análisis estático no lineal-Pushover, a través del cual obtenemos la curva de capacidad de los distintos bloques, encontrando el punto de desempeño sísmico (desp. sísm.) por medio de los métodos del espectro de capacidad propuesto por FEMA 440 y el método de los coeficientes de desplazamiento propuesto por ASCE/SEI 41-13 para constatar si cumple con los objetivos de desp. sísm. seleccionados para el sismo de servicio, sismo de diseño y sismo máximo. Para la institución educativa , clasificada en la NTP E-030 como estructura esencial no se ha llegado a conocer en estudios anteriores el punto de desempeño sísmico de los distintos bloques ,por ende la presente investigación busca llenar un vacío teórico al conocer el comportamiento sísmico de los diferentes bloques de una manera más cercana a la realidad y conocer el punto de desempeño es importante ya que indica si la estructura ante un determinado nivel de sismo tendrá un particular nivel de desempeño estructural lo cual se espera que éste nivel no esté cerca al colapso total de la estructura estudiada. El programa estructural empleado es ETABS , el cual nos permite modelar las diferentes estructuras con las dimensiones tal cual se presentan en los planos de los diferentes bloques, como resultado se obtuvo que las estructuras no llegan a cumplir en su totalidad con los objetivos de desempeño seleccionados para los diferentes niveles de sismo estipuladas en las normativas FEMA 440 y ASCE/SEI 41-13, además de presentar en algunos casos desempeños de colapso generalmente para el nivel de sismo máximo. | es_PE |
| dc.description.abstract | This thesis focuses mainly on analyzing the seismic performance of blocks III, IV and an elevated tank belonging to the Santa Magdalena Sofía I.E. located in the city of Chiclayo, province of Chiclayo, department of Lambayeque. Nonlinear static analysis-Pushover will be used, through which we obtain the capacity curve of the different blocks, finding the seismic performance point through the capacity spectrum methods proposed by FEMA 440 and the displacement coefficient method proposed by ASCE/SEI 41-13 to verify if it meets the seismic performance objectives selected for the service earthquake, design earthquake and maximum earthquake. For the educational institution, classified in NTP E-030 as an essential structure, the seismic performance point of the different blocks has not been known in previous studies. Therefore, the present investigation seeks to fill a theoretical gap by understanding the seismic behavior of the different blocks in a way that is closer to reality. Knowing the seismic performance point is important since it indicates whether the structure will have a particular level of structural performance under a given earthquake level. It is expected that this level will not be close to the total collapse of the structure studied. The structural program used is ETABS, which allows us to model the different structures with the dimensions as presented in the plans of the different blocks. As a result, it was found that the structures do not fully meet the performance objectives selected for the different earthquake levels stipulated in FEMA 440 and ASCE/SEI 41-13 regulations, in addition to presenting collapse performances in some cases, generally for the maximum earthquake level. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Desempeño sísmico | es_PE |
| dc.subject | Análisis no lineal | es_PE |
| dc.subject | Curva de capacidad | es_PE |
| dc.subject | Niveles de sismo | es_PE |
| dc.title | Evaluación del desempeño sísmico de los bloques III, IV y tanque elevado de la I.E Santa Magdalena Sofía, ubicada en la ciudad de Chiclayo, utilizando análisis estático no lineal-pushover | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Civil | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitectura | es_PE |
| thesis.degree.discipline | Ingeniería Civil | es_PE |
| dc.type.version | info:eu-repo/semantics/submittedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
| renati.author.dni | 48819252 | |
| renati.author.dni | 72252521 | |
| renati.advisor.dni | 16716243 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-9558-2853 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 732016 | es_PE |
| renati.juror | Loayza Rivas, Carlos Adolfo | es_PE |
| renati.juror | Rodriguez Serquen, Segundo Arturo | es_PE |
| renati.juror | Cachay Silva, Roberto Carlos | es_PE |