Optimización del sistema eléctrico del Hospital Regional de Lambayeque mediante el mantenimiento basado en condición (CBM) periodo - 2023
| dc.contributor.advisor | Villalobos Cabrera, Jony | es_PE |
| dc.contributor.author | Pérez Pérez, Jorge Luis | es_PE |
| dc.date.accessioned | 2026-07-08T16:06:08Z | |
| dc.date.available | 2026-07-08T16:06:08Z | |
| dc.date.issued | 2026-05-08 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12893/17281 | |
| dc.description.abstract | La presente investigación tuvo como objetivo optimizar el sistema eléctrico del Hospital Regional de Lambayeque mediante la aplicación del mantenimiento basado en condición (CBM), durante el periodo 2023. El estudio fue de tipo aplicado, con diseño no experimental, y consideró como población el sistema eléctrico del hospital, conformado por tableros de distribución, sistema de puesta a tierra, cargas eléctricas, equipos de respaldo y componentes asociados a la continuidad del servicio hospitalario. El diagnóstico permitió identificar que los problemas no se limitan a una falta general de mantenimiento, sino que se presentan por tablero y nivel de criticidad: el tablero general registra la mayor concentración de carga, con 600 A y 224,4 kW; los tableros de 100 A alcanzan 22,0 kW; los de 60 A, 13,2 kW; los de 40 A, 8,8 kW; y los de 30 A, 6,6 kW, evidenciándose necesidad de balance de cargas, termografía, reapriete, limpieza, rotulado, verificación de protecciones y control periódico de demanda. Asimismo, el análisis de calidad de energía registró tensiones fase-fase entre 222 V y 236 V, frecuencia estable de 60 Hz ± 1 %, potencia aparente máxima de 62 kVA y ausencia de picos armónicos críticos; sin embargo, la puesta a tierra presentó valores de 5,60 Ω, 5,45 Ω y 5,35 Ω, superiores al criterio de 5 Ω, por lo que requiere corrección. Se identificaron cargas variables, como climatización, bombas, ascensores y lavandería, y cargas sensibles, como equipos médicos, UPS, quirófanos, UCI, iluminación de emergencia y sistemas de soporte vital. Finalmente, se propuso un plan CBM priorizado, técnica y económicamente viable, con una inversión de S/ 38 000, TIR de 45 % y recuperación aproximada de un año y nueve meses. | es_PE |
| dc.description.abstract | This research aimed to optimize the electrical system of the Lambayeque Regional Hospital through the application of condition-based maintenance (CBM) during the 2023 period. The study was applied in nature, with a non-experimental design, and considered the hospital electrical system as the population, including distribution boards, grounding system, electrical loads, backup equipment, and components associated with hospital service continuity. The diagnosis showed that the problems are not limited to a general lack of maintenance, but occur by board and criticality level: the main distribution board records the highest load concentration, with 600 A and 224.4 kW; the 100 A boards reach 22.0 kW; the 60 A board, 13.2 kW; the 40 A boards, 8.8 kW; and the 30 A boards, 6.6 kW. These results show the need for load balancing, thermography, retightening, cleaning, labeling, protection verification, and periodic demand control. In addition, the power quality analysis recorded phase- to-phase voltages between 222 V and 236 V, stable frequency of 60 Hz ± 1 %, maximum apparent power of 62 kVA, and no critical harmonic peaks; however, the grounding system presented values of 5.60 Ω, 5.45 Ω, and 5.35 Ω, exceeding the 5 Ω criterion and therefore requiring correction. Variable loads were identified, such as air conditioning, pumps, elevators, and laundry equipment, as well as sensitive loads, such as medical equipment, UPS, operating rooms, ICU, emergency lighting, and life-support systems. Finally, a prioritized CBM plan was proposed, technically and economically feasible, with an investment of S/ 38,000, an IRR of 45 %, and an estimated payback period of one year and nine months. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Sistema eléctrico | es_PE |
| dc.subject | Mantenimiento basado en condición | es_PE |
| dc.subject | Calidad de Energía Eléctrica | es_PE |
| dc.subject | Criticidad | es_PE |
| dc.title | Optimización del sistema eléctrico del Hospital Regional de Lambayeque mediante el mantenimiento basado en condición (CBM) periodo - 2023 | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Mecánico Electricista | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Mecánica y Eléctrica | es_PE |
| thesis.degree.discipline | Ingeniería Mecánica y Eléctrica | es_PE |
| dc.type.version | info:eu-repo/semantics/submittedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.02.01 | es_PE |
| renati.author.dni | 73113794 | |
| renati.advisor.dni | 16699530 | |
| renati.advisor.orcid | https://orcid.org/0000-0003-3643-5498 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 713076 | es_PE |
| renati.juror | Méndez Cruz, Oscar | es_PE |
| renati.juror | Tapia Asenjo, Robinson | es_PE |
| renati.juror | Cotrina Saavedra, Carlos Javier | es_PE |