Evaluación de la calidad de los muros portantes de viviendas autoconstruidas en el distrito de José Leonardo Ortiz
| dc.contributor.advisor | Borja Suarez, Manuel Alejandro | es_PE |
| dc.contributor.author | Goicochea Dávila, Jaime Alexander | es_PE |
| dc.date.accessioned | 2026-07-14T14:42:18Z | |
| dc.date.available | 2026-07-14T14:42:18Z | |
| dc.date.issued | 2026-06-10 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12893/17339 | |
| dc.description.abstract | La presente investigación tuvo como objetivo evaluar la calidad de los muros portantes en viviendas autoconstruidas del distrito de José Leonardo Ortiz, mediante la comparación de las características físico-mecánicas del ladrillo y del mortero con los requisitos establecidos en la Norma Técnica E.070 – Albañilería. El estudio se desarrolló sobre una muestra de 16 viviendas en proceso de construcción, en las cuales se identificó el tipo de unidad empleada y se realizaron ensayos de variabilidad dimensional, alabeo, resistencia a compresión de la unidad (f’b), porcentaje de área de vacíos, resistencia a compresión del mortero (f’c), resistencia a compresión axial de la albañilería (f’m) y resistencia a compresión diagonal (v’m). Los resultados evidenciaron que el 50% de las viviendas emplea ladrillo artesanal, el 31.25% ladrillo industrial perforado y el 18.75% unidades tubulares. En cuanto a la clasificación normativa, el 75% de las unidades evaluadas no cumple con los requisitos establecidos por la Norma E.070, principalmente por presentar valores insuficientes de resistencia a compresión (f’b). Asimismo, en las viviendas donde se emplearon ladrillos perforados se observó que el 100% de dichas unidades superó el límite máximo permitido de área de vacíos (30%) establecido por la Norma. Respecto al comportamiento estructural, solo el 12.5% de los muros evaluados alcanzó la resistencia mínima a compresión axial (f’m), mientras que el 100% presentó valores de resistencia a compresión diagonal (v’m) inferiores al mínimo normativo, evidenciando una deficiente capacidad frente a solicitaciones sísmicas. En conclusión, los resultados confirman que una proporción significativa de los muros portantes en viviendas autoconstruidas del distrito presenta una calidad físico-mecánica insuficiente para cumplir con los requisitos normativos vigentes, lo que compromete su desempeño estructural en una zona de alta sismicidad. | es_PE |
| dc.description.abstract | The present research aimed to evaluate the quality of load-bearing walls in self-built houses located in the district of José Leonardo Ortiz by comparing the physical-mechanical characteristics of bricks and mortar with the requirements established in the Peruvian Technical Standard E.070 – Masonry. The study was conducted on a sample of 16 houses under construction, in which the type of masonry unit used was identified and tests of dimensional variability, warping, unit compressive strength (f’b), percentage of void area, mortar compressive strength (f’c), axial compressive strength of masonry (f’m), and diagonal compressive strength (v’m) were performed. The results showed that 50% of the houses use artisanal bricks, 31.25% use industrial perforated bricks, and 18.75% use tubular units. Regarding the normative classification, 75% of the evaluated units do not comply with the requirements established by Standard E.070, mainly due to insufficient compressive strength (f’b). Likewise, in the houses where perforated bricks were used, it was observed that 100% of these units exceeded the maximum allowable void area limit (30%) established by the standard. In terms of structural behavior, only 12.5% of the evaluated walls reached the minimum axial compressive strength (f’m), while 100% presented diagonal compressive strength (v’m) values below the normative minimum, indicating a deficient capacity against seismic demands. In conclusion, the results confirm that a significant proportion of load-bearing walls in self-built houses in the district present insufficient physical-mechanical quality to comply with current regulatory requirements, which compromises their structural performance in a high seismicity zone. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Albañilería confinada | es_PE |
| dc.subject | Calidad estructural | es_PE |
| dc.subject | Resistencia a compresión | es_PE |
| dc.subject | Muros portantes | es_PE |
| dc.subject | Autoconstrucción | es_PE |
| dc.title | Evaluación de la calidad de los muros portantes de viviendas autoconstruidas en el distrito de José Leonardo Ortiz | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Civil | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitectura | es_PE |
| thesis.degree.discipline | Ingeniería Civil | es_PE |
| dc.type.version | info:eu-repo/semantics/submittedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
| renati.author.dni | 77472846 | |
| renati.advisor.dni | 16690047 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-6532-4976 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 732016 | es_PE |
| renati.juror | Capuñay Capuñay, Yrma del Carmen | es_PE |
| renati.juror | Serrano Zelada, Ovidio | es_PE |
| renati.juror | Bernilla Gonzales, Jannina Beatriz | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Ingeniería Civil [373]