El empleo del aditivo espumante y su influencia en las propiedades físicas y mecánicas del concreto en bloques huecos para albañilería no estructural
| dc.contributor.advisor | Huangal Castañeda, Nelson Enrique | es_PE |
| dc.contributor.author | Lingan Mendoza, Marco Chayanne | es_PE |
| dc.contributor.author | Rubio Cieza, Lenin Alfredo | es_PE |
| dc.date.accessioned | 2026-07-16T16:59:40Z | |
| dc.date.available | 2026-07-16T16:59:40Z | |
| dc.date.issued | 2026-06-23 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12893/17363 | |
| dc.description.abstract | La presente investigación tuvo como finalidad evaluar la incidencia del aditivo espumante sobre las propiedades físicas y mecánicas del concreto empleado en la fabricación de bloques huecos destinados a albañilería no estructural. El estudio se desarrolló bajo un enfoque cuantitativo, de carácter aplicado y con diseño experimental. Se elaboraron tres mezclas con dosificaciones de 1.0, 1.5 y 2.0 kg/m3 de aditivo, evaluando su función en estado fresco y endurecido. Para el diseño de mezcla se adoptó una relación agua/cemento de 0.50, utilizando 384.26 kg/m3 de cemento, 948.92 kg/m3 de agregado y 205.84 kg/m3 de agua, verificándose condiciones adecuadas de trabajabilidad durante el proceso de elaboración. Los resultados evidenciaron un incremento del aditivo hasta 99.10% no alteró el agua (variación <0.5%) ni la relación a/c (0.533 a 0.530), manteniendo la consistencia de la mezcla. Sin embargo, en la resistencia a compresión a 28 días, se registraron valores de 43.04, 37.56 y 28.17 kg/cm2 para las muestras M1, M2 y M3, respectivamente. A pesar de ello, todas las mezclas incrementaron su resistencia entre 45.9% y 50.0%, evidenciando un adecuado desarrollo del proceso de hidratación del cemento. Se concluye que el aditivo espumante reduce la resistencia, pero permite obtener un material más liviano, siendo viable en usos no estructurales. | es_PE |
| dc.description.abstract | The purpose of this research was to evaluate the influence of the foaming additive on the physical and mechanical properties of concrete used in the manufacture of hollow blocks for non-structural masonry. The study was conducted under a quantitative approach, with an applied nature and an experimental design. Three mixtures were prepared with additive dosages of 1.0, 1.5, and 2.0 kg/m3, assessing their performance in both fresh and hardened states. For the mix design, a water-cement ratio of 0.50 was adopted, using 384.26 kg/m3 of cement, 948.92 kg/m3 of aggregate, and 205.84 kg/m3 of water, while adequate workability conditions were verified during the manufacturing process. The results showed that increasing the additive up to 99.10% did not alter the water content (variation <0.5%) or the w/c ratio (0.533 to 0.530), maintaining the consistency of the mixture. However, for compressive strength at 28 days, values of 43.04, 37.56, and 28.17 kg/cm2 were recorded for the samples M1, M2, and M3, respectively. Despite this, all mixtures increased their strength by between 45.9% and 50.0%, indicating adequate development of the cement hydration process. It is concluded that the foaming additive reduces strength but allows for a lighter material, making it viable for non-structural applications. | es_PE |
| dc.format | application/pdf | es_PE |
| dc.language.iso | spa | es_PE |
| dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
| dc.rights | info:eu-repo/semantics/openAccess | es_PE |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
| dc.subject | Resistencia a compresión | es_PE |
| dc.subject | Concreto | es_PE |
| dc.subject | Aditivo espumante | es_PE |
| dc.subject | Foaming additive | es_PE |
| dc.title | El empleo del aditivo espumante y su influencia en las propiedades físicas y mecánicas del concreto en bloques huecos para albañilería no estructural | es_PE |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_PE |
| thesis.degree.name | Ingeniero Civil | es_PE |
| thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitectura | es_PE |
| thesis.degree.discipline | Ingeniería Civil | es_PE |
| dc.type.version | info:eu-repo/semantics/submittedVersion | es_PE |
| dc.publisher.country | PE | es_PE |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.01 | es_PE |
| renati.author.dni | 77465947 | |
| renati.author.dni | 75612757 | |
| renati.advisor.dni | 40774977 | |
| renati.advisor.orcid | https://orcid.org/0000-0003-1526-4263 | es_PE |
| renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
| renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es_PE |
| renati.discipline | 732016 | es_PE |
| renati.juror | Farias Feijoo, Juan Herman | es_PE |
| renati.juror | Blas Rebaza, Rocío del Pilar | es_PE |
| renati.juror | Davila Vidarte, Domingo Jorge Luis | es_PE |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Ingeniería Civil [374]