Eficiencia del sistema de tratamiento de aguas residuales lagunas de estabilización San José en la calidad físico-química, microbiológica y en la concentración de metales pesados de las aguas residuales de la ciudad de chiclayo, abril-junio del 2007
dc.contributor.advisor | Vasquez Garcia, Antero Celso | es_PE |
dc.contributor.author | Vargas Machuca Seminario, Onofre Alberto | es_PE |
dc.date.accessioned | 2025-02-06T04:23:00Z | |
dc.date.available | 2025-02-06T04:23:00Z | |
dc.date.issued | 2018-03-27 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12893/14041 | |
dc.description.abstract | La investigación tiene como propósito evaluar la eficiencia del Sistema de tratamiento de Agua residual Lagunas de Estabilización San José administrada por EPSEL SA, fue actualizado durante los meses de abril, mayo y junio de 2017. Las muestras se tomaron según los criterios de la APPHA y el Stándar Methods for Water Analys y se almacenaron en enfriadores y se transportaron al laboratorio NKAP SRL en Trujillo, Perú. Se realizaron análisis físicos, químicos y microbiológicos, midiendo la temperatura, pH y oxígeno disuelto. Se determinaron la concentración de metales y los resultados se compararon con los LMP fijados con la normatividad. La eficiencia del tratamiento se determinó por diferencia entre el valor de cada parámetro en el afluente y el valor de cada parámetro en el efluente expresado en porcentaje. Se determinó que la eficacia del sistema de tratamiento varía en función de la concentración de diferentes parámetros, como los Sólidos Suspendidos Totales, la Demanda Bioquímica de Oxígeno, la Demanda Química de Oxígeno y los Aceites y Grasas. La eficiencia del sistema en la remoción de Coliformes termotolerantes fue alta, pero la concentración de NMP/100mL en el efluente era mayor al LMP establecido por la normatividad existente. Se sugiere la utilización de métodos de tratamiento alternativos, como el empleo de ozono y lámparas de rayos ultravioleta, con el fin de reducir la concentración de coliformes termotolerantes en el agua del efluente. | es_PE |
dc.description.abstract | The purpose of the investigation is to evaluate the efficiency of the San José Stabilization Lagoons residual water treatment system administered by EPSEL SA, was updated during the months of April, May and June 2017. The samples were taken according to the APPHA criteria and the Standard Methods for Water Analys and are stored in coolers and transported to the NKAP SRL laboratory in Trujillo, Peru. Physical, chemical and microbiological analyzes were carried out, measuring temperature, pH and dissolved oxygen. The concentration of metals was determined and the results were compared with the LMP established by DS 003-2010-MINAM. The efficiency of the treatment will be prolonged by the difference between the value of each parameter in the tributary and the value of each parameter in the effluent expressed as a percentage. It was concluded that the efficiency of the treatment system varied in relation to the concentration of Total Suspended Solids, Biochemical Oxygen Demand, Chemical Oxygen Demand, and Oils and Greases. The efficiency of the system in the removal of thermotolerant coliforms was high, but the concentration of NMP/100mL in the effluent was higher than the LMP set by DS 003-2010- MINAM. The use of alternative treatments such as ozone and UV lamps is proposed to minimize the concentration of thermotolerant coliforms in the effluent water | es_PE |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Universidad Nacional Pedro Ruiz Gallo | es_PE |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_PE |
dc.subject | Tratamiento del agua | es_PE |
dc.subject | Aguas residuales | es_PE |
dc.subject | Calidad del agua | es_PE |
dc.subject | Water treatment | es_PE |
dc.subject | Waste water | es_PE |
dc.subject | Water quality | es_PE |
dc.title | Eficiencia del sistema de tratamiento de aguas residuales lagunas de estabilización San José en la calidad físico-química, microbiológica y en la concentración de metales pesados de las aguas residuales de la ciudad de chiclayo, abril-junio del 2007 | es_PE |
dc.type | info:eu-repo/semantics/masterThesis | es_PE |
thesis.degree.name | Maestro en Ciencias con mención en Ingeniería Ambiental | es_PE |
thesis.degree.grantor | Universidad Nacional Pedro Ruiz Gallo - Escuela de Posgrado | es_PE |
thesis.degree.discipline | Maestría en Ciencias con mención en Ingeniería Ambiental | es_PE |
dc.type.version | info:eu-repo/semantics/draft | es_PE |
dc.publisher.country | PE | es_PE |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.07.01 | es_PE |
renati.author.dni | 16421031 | |
renati.advisor.dni | 1789632 | |
renati.advisor.orcid | https://orcid.org/0000-0002-8977-3274 | es_PE |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es_PE |
renati.level | http://purl.org/pe-repo/renati/nivel#maestro | es_PE |
renati.discipline | 521287 | es_PE |
renati.juror | Vargas Rosado, Cesar Alfredo | es_PE |
renati.juror | Carreño Farfán, Carmen Rosa | es_PE |
renati.juror | Llontop Barandiaran, Gianina | es_PE |