Mostrar el registro sencillo del ítem

dc.contributor.advisorSerrano Zelada, Ovidioes_PE
dc.contributor.authorOblitas Diaz, Juan Carloses_PE
dc.date.accessioned2026-09-08T17:14:10Z
dc.date.available2026-09-08T17:14:10Z
dc.date.issued2026-08-17
dc.identifier.urihttps://hdl.handle.net/20.500.12893/17667
dc.description.abstractLa ingeniería estructural sismorresistente en las últimas décadas ha tenido innovaciones en cuanto a técnicas de construcción que buscan que las estructuras tengan un mejor desempeño estructural ante un sismo garantizando la seguridad y la vida de las personas, se ha observado que tras un sismo algunas edificaciones convencionales presentan daños cuyos costos de reparación superan lo previsto. Aproximadamente 18 millones de habitantes viven en zonas con alto riesgo sísmico en el Perú. La presente investigación tiene como objetivo realizar el análisis comparativo técnico económico de un edificio de 8 niveles con y sin amortiguadores de fluido viscoso en el Distrito de Pimentel – Chiclayo, el área del terreno del proyecto es de 290.52m2, por lo que se analiza y diseña el edificio convencionalmente con un sistema de muros estructurales, como segunda alternativa se analiza y diseña el edificio con Disipadores de Fluido Viscoso (DFV); el análisis tiempo-historia con 7 pares de registros sísmicos fue el método utilizado para analizar la estructura con DFV linealmente y no lineal. El edificio diseñado convencionalmente presentó derivas de 0.065 en X y de 0.056 en Y, por su parte en el edificio con DFV se logró derivas de 0.059 en X y de 0.0055 en Y, cumpliendo en ambos casos con la norma E.030. El edificio con sistema de protección sísmica presentó un mejor comportamiento estructural dado que la energía entrante total de un sismo en un 60% es disipada por los disipadores de energía, mientras que en el edificio convencional el 100% de le energía producto del sismo es tomada por los elementos estructurales; en costos la incidencia del edificio con disipadores sobre el edificio convencional es de 14%, porcentaje menor al de reparación de edificios posterior a un sismo 15 a 20%.es_PE
dc.description.abstractIn recent decades, earthquake-resistant structural engineering has seen innovations in construction techniques aimed at improving the structural performance of buildings during earthquakes, thus ensuring the safety and well-being of people. It has been observed that after an earthquake, some conventional buildings sustain damage with repair costs exceeding initial estimates. Approximately 18 million people live in areas with high seismic risk in Peru. The objective of this research is to carry out the technical-economic comparative analysis of an 8-story building with and without viscous fluid dampers in the Pimentel District – Chiclayo. The project site area is 290.52m2. The building is analyzed and designed conventionally, featuring a structural wall system. As a second alternative, the building is analyzed and designed with Viscous Fluid Dampers (VFD). Time-history analysis with 7 pairs of seismic records was the method used to analyze the structure with VFD linearly and non-linearly. The conventionally designed building exhibited drifts of 0.065 in X and 0.056 in Y, while the building with a DFV (Dynamic Dissipation Factor) achieved drifts of 0.059 in X and 0.0055 in Y, both complying with standard E.030. The building with a seismic protection system showed better structural performance, as 60% of the total incoming energy of an earthquake is dissipated by the energy dissipators, whereas in the conventional building, 100% of the energy from the earthquake is absorbed by the structural elements. In terms of cost, the impact of the building with dissipators on the conventional building is 14%, a percentage lower than the 15-20% cost of repairing buildings after an earthquake.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional Pedro Ruiz Galloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectEstructurases_PE
dc.subjectAmortiguadoreses_PE
dc.subjectSismoresistentees_PE
dc.subjectDamperses_PE
dc.titleAnálisis comparativo técnico-económico de un edificio de 8 pisos con y sin amortiguadores de fluido viscoso en el distrito de Pimentel provincia de Chiclayo-departamento de Lambayequees_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.nameIngeniero Civiles_PE
thesis.degree.grantorUniversidad Nacional Pedro Ruiz Gallo - Facultad de Ingeniería Civil, Sistemas y Arquitecturaes_PE
thesis.degree.disciplineIngeniería Civiles_PE
dc.type.versioninfo:eu-repo/semantics/submittedVersiones_PE
dc.publisher.countryPEes_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.01es_PE
renati.author.dni73881546
renati.advisor.dni16716243
renati.advisor.orcidhttps://orcid.org/0000-0002-9558-2853es_PE
renati.typehttp://purl.org/pe-repo/renati/type#tesises_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.jurorFarias Feijoo, Juan Hermanes_PE
renati.jurorCueva Campos, Hamilton Vladimires_PE
renati.jurorCapuñay Capuñay, Yrma del Carmenes_PE


Ficheros en el ítem

Thumbnail
Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess
Universidad Nacional Pedro Ruiz Gallo

Calle Juan XXIII 391 Lambayeque - Perú | Telf. 283146 - 283115 - 282120 - 282356

Todos los contenidos de repositorio.unprg.edu.pe están bajo la Licencia Creative Commons v.4.0

repositorio@unprg.edu.pe